Page 2
Chicago Pneumatic Compressors
62 305 258 65
The CP Compressors should never be operated beyond its capabilities
or in any way which does not comply with the instructions contained
in this operating and maintenance guide.
Chicago Pneumatic Compressors will decline any responsibility
if these instructions are not respected.
This equipment has been factory tested and satisfies normal
operating conditions: they must not be exceeded
as this would place the machine under abnormal stress and effort.
INSTALLATION INSTRUCTIONS
For the guarantee to be valid, the unit must be assembled in covered
premises with temperatures not exceeding :
Mini: + 36 °F (frost free)
Maxi: + 104 °F
You must also have:
1 meter space around the compressor
-
low ventilation (fresh air) proportionate to the ventilation flow necessary for the machine and protected
from any infiltration of humidity (splashes of water during bad weather) and all pollution
-
top insulation or extraction to ensure reversal of the flow of warm air and evacuation of the heat to
outside the equipment room
-
a link from the condensation water evacuation pipe to the drain discharger
-
in dusty environment, pre-filtering the room's air intake and a special filter
on the machine's ventilation inlets
TECHNICAL DATA
VARIABLE SPEED MACHINES
CPVS Model 40 50 60 75
VERSION CPVS (as per ISO 1217 ed 1996)
Nominal pressure at full flow PSI 58 102 138 58 102 138 58 102 138 58 102 138
Actual flow* cfm 195.1 194.5 166.4 239.1 234.1 204.4 291.2 280.2 244.7 374.3 342.3 304.8
Motor power hp 40 50 60 75
Ø Pressure outlet (F) NPT 1.5" 1.5" 1.5" 1.5"
Capacity gal 5,8 5,8 5,8 5,8
Carryover ppm 3 3 3 3
Noise level at 3,3ft dB(A) 65 66 67 70
(according to ISO 2157 + 3db(A))
* Suction pressure : 14.5 PSI absolute - Relative humidity : 0 % - Ambient temperature : 68 °F
- Effective delivery pressure : 102 PSI, 109 PSI, 138 PSI or 181 PSI (effective)
Dimensions (in) L x Wx H 75x37,4x69,3 75x37,4x69,3 75x37,4x69,3 75x37,4x69,3
Approximate weight lbs 1874 1995 2226 2679